Class HLLPolicy

A policy affecting the behavior of HLL commands.

v3.16.0

Hierarchy (view full)

Constructors

Properties

compress?: boolean

Use zlib compression on write or batch read commands when the command buffer size is greater than 128 bytes. In addition, tell the server to compress it's response on read commands. The server response compression threshold is also 128 bytes.

This option will increase cpu and memory usage (for extra compressed buffers), but decrease the size of data sent over the network.

Requires Enterprise Server version >= 4.8.

@default: false

v3.14.0

filterExpression?: AerospikeExp

Optional expression filter. If filter exp exists and evaluates to false, the command is ignored. This can be used to eliminate a client/server roundtrip in some cases.

expression filters can only be applied to the following commands:

maxRetries?: number

Maximum number of retries before aborting the current command. The initial attempt is not counted as a retry.

If maxRetries is exceeded, the command will return error ERR_TIMEOUT.

WARNING: Database writes that are not idempotent (such as "add") should not be retried because the write command may be performed multiple times if the client timed out previous command attempts. It is important to use a distinct write policy for non-idempotent writes which sets maxRetries to zero.

@default: 2 (initial attempt + 2 retries = 3 attempts)

socketTimeout?: number

Socket idle timeout in milliseconds when processing a database command.

If socketTimeout is not zero and the socket has been idle for at least socketTimeout, both maxRetries and totalTimeout are checked. If maxRetries and totalTimeout are not exceeded, the command is retried.

If both socketTimeout and totalTimeout are non-zero and socketTimeout > totalTimeout, then socketTimeout will be set to totalTimeout. If socketTimeout is zero, there will be no socket idle limit.

0 (no socket idle time limit).
totalTimeout?: number

Total command timeout in milliseconds.

The totalTimeout is tracked on the client and sent to the server along with the command in the wire protocol. The client will most likely timeout first, but the server also has the capability to timeout the command

If totalTimeout is not zero and totalTimeout is reached before the command completes, the command will return error ERR_TIMEOUT. If totalTimeout is zero, there will be no total time limit.

1000

Transaction identifier. See Transaction for more information.

null (no transaction)
writeFlags: hll.writeFlags

Specifies the behavior when writing byte values.

hll.writeFlags.DEFAULT

hll.writeFlags for supported policy values.

MMNEPVFCICPMFPCPTTAAATR